| PS12T Perfomance Specification
|
| Product |
Moisture |
Production/Hour |
| Polyester |
14%-2% |
100 kgs |
| Acrylic |
15%-2% |
100 kgs |
| Polyamide |
18%-3% |
100 kgs |
| Wool/Acrylic |
33%-11% |
70 kgs |
| Wool |
42%-17% |
55 kgs |
| Poly/Cotton |
30%-5% |
50 kgs |
| Cotton |
52%-8% |
30 kgs |
| Viscose |
80%-11% |
20 kgs |
|
E200 Operator System
This system has the capacity to pre-set operating parameters for various product menus. The most
commonly used machine settings are easily entered. The operator can select the required product
by the simple push of a button.
Full Fault Diagnostic System
If a fault occurs, the cause of a fault is immediately displayed for the operator to see. The
fault display also provides information to the operator on the relevant circuit reference where
the fault has occured and gives a list of check items to clear the fault.
Built-in Maintenance Reminders
The E200 Operator screen automatically displays when maintenance should be undertaken and provides
a message to the operator.
|